ESI-32 : Diagnostics (Magic Mode)
Diagnostics and Trims
The ESI is a complex electronic instrument. Luckily E-mu Systems have provided a diagnostic mode within the Operating System to help troubleshooting, when something goes wrong. However be VERY careful using these functions, some can cripple your sampler and mean a trip to the service cente.
Enter The Magic Code To get to the diagnostic routines you need
to go into the MASTER module and enter 8. In the SPECIAL module enter 0, and the LCD will display:
DIAGNOSTICS Enter MagicCode
Enter numeric 1358.
The display will now show:
DIAGNOSTICS Select a Submodule
PLEASE be
very careful with these tests - some are DESTRUCTIVE to your sample data !!
Diagnostic Submodules
There are 10 submodules that can be selected and exited in the normal way, except the Panel Test which needs enter pushing twice.
|
|
|
|
|
|
|
|
Checks out every front panel button and the LCD
|
|
|
|
|
|
Checks out the CPU and sample RAM, this takes a long time !
|
|
|
|
|
|
|
|
|
|
Tests the submix output jack
|
|
|
|
|
|
Checks out the turbo FX chip
|
|
|
|
|
|
Resets the EEPROM to factory defaults after verifying
|
|
|
|
|
|
|
|
|
|
Emits a 1kHz or 19kHz test signal
|
|
|
|
|
|
Tests CPU RAM, G-chip, sound RAM and hard drive.This test destroys all hard disk data
!!!
|
|
|
|
|
|
Checks out the floppy and hard disk drive with a variety of tests
|
|
|
|